Heated platen

Thermal FEA of heater placement, interface contact, surface losses and controlled warm-up.

Completed commissioning study

Three heaters with nominal 1000 W/(m 2 K) contact, bottom U 2 W/(m 2 K), 60 W maximum power, independent 125 C heater/105 C surface cutoff with 2 s response. Six 22/35 C ambient x 5/10/20 W/(m 2 K) convection cases reach 88-92 C across the working area for a 300 s hold.

Executed synthetic/theoretical results, rejected cases and acceptance matrix. Source: complete_validation.py.

Model

Steady results

layoutpoor_contacttop_h_W_m2Kminimum_working_Cmaximum_working_Cmaximum_heater_Cin_band
evenFalse5124.913125.96130.489False
evenFalse1089.04390.094.581True
evenFalse2061.44262.32866.95False
evenTrue5124.522125.591171.736False
evenTrue1088.77989.758136.39True
evenTrue2061.27862.185109.194False
edgeFalse5124.993125.743130.271False
edgeFalse1089.0889.85694.437True
edgeFalse2061.44762.24166.862False
edgeTrue5124.613125.387171.767False
edgeTrue1088.82889.627136.456True
edgeTrue2061.29462.11109.286False
centralFalse5124.52126.507131.007False
centralFalse1088.63790.53995.092True
centralFalse2061.02962.85867.452False
centralTrue5124.135126.137172.072False
centralTrue1088.3890.296136.697True
centralTrue2060.87162.715109.476False

Warm-up

casesettled_in_band_sfinal_min_Cfinal_max_Cpeak_heater_Cpeak_working_C
nominal-h5200689.12189.817102.94699.22
nominal-h10201888.85989.822102.05696.757
nominal-h20189088.4389.922101.0692.834
poor-h5200089.12889.842178.46299.345
poor-h10201288.84489.832181.97796.835
poor-h20189288.38789.921190.90192.852

Verification

dt_ssettled_in_band_sfinal_min_Cpeak_working_C
4202088.859302751146296.77046970444238
2201888.8594639024431496.75667182826378
1201788.8594569621171296.726739829556

Bench plan

Limits

Numerical library reference

scikit-fem heat equation example. The supplied model adds finite heater contact, distributed losses and lumped heater capacities.

Equal-power temperature comparison
Equal-power temperature comparison
Controlled warm-up and heater temperatures
Controlled warm-up and heater temperatures
Thermocouple layout
Thermocouple layout

Reference design by CJ Ackley. Numerical and geometry checks are not a physical qualification.